The advantage of the LUGB series plug-in vortex flowmeter is its excellent vibration resistance, zero drift free, and high reliability. Through extensive waveform and spectrum analysis of vortex flowmeters over a long period of time, better probe shape, wall thickness, height, probe rod diameter, and corresponding piezoelectric crystals are designed. Advanced CNC lathes are used for processing to ensure the coaxiality and smoothness of the processed technical parameters, combined with special process processing, to overcome the common problem of the inherent self oscillation frequency of vortex flowmeters affecting the signal.
The structure is simple and sturdy, without movable components, with high reliability and reliable long-term operation;
Easy installation and very convenient maintenance;
The detection sensor does not directly contact the tested medium, with stable performance and long service life;
The output is a pulse signal proportional to the flow rate, with no zero drift and high accuracy;
Wide measurement range, with a range ratio of up to 1:10;
Less pressure loss, lower operating costs, and more energy-saving significance;
Within a certain Reynolds number range, the output signal frequency is not affected by the physical properties and composition changes of the fluid. The instrument coefficient is only related to the shape and size of the vortex generator, and there is no need to compensate when measuring the volume flow rate of the fluid. After replacing accessories, there is generally no need to recalibrate the instrument coefficient;
Wide application range, steam (saturated steam), gas (air, oxygen, nitrogen, gas, natural gas, gas, hydrogen, liquefied petroleum gas, hydrogen peroxide, flue gas, methane, butane, chlorine, gas, biogas, carbon dioxide, nitrogen, acetylene, phosgene, oxygen, compressed air, argon, toluene, benzene, xylene, hydrogen sulfide, sulfur dioxide, ammonia), steam, liquid, and water, etc.) The flow rates of liquids (water, high-temperature water, oil, food liquids, chemical liquids, etc.), liquids, and gases can be measured.
Measurement medium |
Liquid; Gas; Saturated steam; superheated steam |
accuracy class |
±2.5% |
Working pressure |
1.6MPa |
medium temperature |
Ordinary type -40~+150 ℃; Medium temperature type -40~+250 ℃; High temperature type -40~+350 ℃ |
output signal |
Three wire voltage pulse; Low level 0-1V; High level>4V; 50% duty cycle; Two wire standard current 4-20mA; Three wire standard current 0-10mA |
work environment |
-35 ℃~+60 ℃, humidity ≤ 95% RH |
Working power supply |
DC12V; DC24V |
Shell Material |
Carbon steel; Stainless steel |
Explosion proof type |
Intrinsically safe ExibIICT6 |