Non full tube electromagnetic flowmeter

The DPLLD/F type non full tube electromagnetic flowmeter is composed of a flow rate sensor, a water level sensor, and a flow display instrument. It continuously measures the flow rate and liquid level of the fluid in the pipeline. As long as the user inputs the inner diameter of a circular pipeline or the width of a square pipeline, the non full tube flowmeter will automatically calculate the flow rate in the pipeline and display measurement parameters such as instantaneous flow rate, flow rate, and cumulative flow rate in the pipeline.

Product Characteristics

Can be used for measuring the flow rate of open non full pipe pipelines;

It can be applied to continuous measurement of municipal rainwater, wastewater, sewage discharge, and irrigation water pipelines;

Can achieve bidirectional flow measurement in both forward and reverse directions;

The sensor can work for a long time in harsh on-site conditions and sewage quality;

The flow measurement accuracy is high, and it is not affected by downstream and tributary congestion, blockages, and other factors;

The straight section of the measuring pipeline requires a length of 10 times the diameter of the pipeline;

Backlit LCD display, capable of clearly reading measurement data under strong light or at night;

The non full tube flowmeter has complete display and output functions, which can display instantaneous flow rate, flow rate, cumulative flow rate, and other data. It also has computer communication interfaces 232 and 485 (optional accessories).

Product ParameterDocument Download

Nominal Diameter

Circular pipeline DN200-DN1000

Overall measurement accuracy

Level 2.5

Lining material

Neoprene rubber

Electrode material

316L;  Hastelloy B;  Hastelloy C;  Titanium;  Tantalum;  Stainless steel coated with tungsten carbide

Electrode form

Standard type

Connection method

Flange connection

working conditions

Environmental temperature: -10~+60 ℃ (liquid in the pipeline will not freeze)

Relative humidity: 5%~90%

nominal pressure

0.6MPa;1.0MPa;1.6MPa

power supply

AC220V;DC24V;12V

Dielectric conductivity

≥20μs/cm

ambient humidity

5-100% RH (relative humidity)

measuring range

1500:1 flow rate setting<15m/s

structural style

Splitting type;  immersion

protection grade

IP68 optional

Explosion proof sign

ExdIICT 4

Product standards

JB/T9248-2015 Electromagnetic Flowmeter