The DPLLZ series metal tube float flowmeter has an all metal structure, including indicator type (pointer display, LCD display), electric remote transmission type, corrosion resistant type, high-voltage type, jacket type, and explosion-proof type.
Equipped with standard analog signal output and on-site indication of 0-10mA and 4-20mA. At the same time, it has functions such as accumulation, digital communication, and can modify measurement parameters on site. Different power supply methods can be selected based on on-site conditions, and magnetic filters and special specifications are available for selection.
measuring range |
Water (2.5-150000) L/h; Air (0.07-2000) m3/h (at 0.101325 Mpa, 20 ℃) |
accuracy class |
Level 1.5; Grade 2.5 (PTFE) |
Range ratio |
10: 1 or special 5:1 |
nominal pressure |
DN15~DN50≤4.0MPa; DN65~DN150 ≤1.6MPa |
medium temperature |
-80℃~200℃(lined F46 flow meter 0℃~80℃) |
Liquid medium viscosity |
DN15<5mPa•s; DN25~150≤250mPa•s |
output |
4-20mA two wire system |
Pure resistive load |
<680Ω |
Linearity |
<0.5% |
Temperature effect |
<5MA/K |
ambient temperature |
-25℃~55℃ |
Total height |
DN15~DN150 (usually 250mm) |