Home  >  Products  >  Electromagnetic Flowmeter
Ceramic lined electromagnetic flowmeter

The difference between DPLLD series ceramic lined electromagnetic flowmeters and general flowmeters lies in the use of ceramic materials as lining, which can achieve high temperature resistance, smooth inner surface, less retention of debris, and easy disinfection. The ceramic lined electromagnetic flowmeter has no movable components inside and the inner wall is relatively smooth, which is convenient for steam cleaning and disinfection, thus achieving safety and hygiene without bacterial residue.

Product Characteristics

The structure of the electromagnetic flowmeter sensor is simple, and there are no movable components in the measuring tube, and there are no throttling components that hinder fluid flow;

Can measure the flow rate of dirty, corrosive, and suspended liquid-solid two-phase flow;

During the measurement process, it is not affected by the temperature, viscosity, density, or conductivity (within a certain range) of the measured medium;

The output of an electromagnetic flowmeter is only proportional to the average flow velocity of the measured medium, and is independent of the flow state (laminar or turbulent) under symmetrical distribution;

Electromagnetic flowmeters have no mechanical inertia and are sensitive in response. They can measure instantaneous pulsating flow and can also measure flow in both positive and negative directions;

The caliber selection range of industrial electromagnetic flow meters is wide.

Product ParameterDocument Download

Nominal Diameter

DN25——DN350mm

accuracy

± 0.5% of the indicated value;  ± 0.3% or ± 0.2% of optional indication

Lining material

Zirconium dioxide

Electrode material

Titanium diboride

Electrode form

Standard type

Connection method

Flange connection

medium temperature

-20℃~+180℃

nominal pressure

1.0~1.6MPa (special pressure can be customized)

ambient temperature

-25℃~+60℃

ambient humidity

5-100% RH (relative humidity)

Dielectric conductivity

≥20μs/cm

measuring range

1500:1 flow rate setting<15m/s

structural style

One body type;  Splitting type

protection grade

IP65; IP68 optional

Explosion proof sign

ExdIICT 4

Product standards

JB/T9248-2015 Electromagnetic Flowmeter