Home  >  FAQ
FAQ
  • Gas turbine flowmeter: cumulative flow indication and repeatability exceed the range of standard error influence 关闭

    1. When the instrument coefficient input is incorrect, a correct instrument coefficient should be input based on the calibration analysis results.


    2. If the normal flow rate of the user is lower or higher than the normal flow range of the selected flowmeter, the appropriate specification of the flowmeter should be selected again based on the pipeline flow rate.


    3. When there are many impurities in the medium that cause abnormal operation of the mass flowmeter turbine, various pipeline systems should be cleaned. After removing the flowmeter turbine, thoroughly clean it with light and high-grade gasoline and reinstall it.

  • Gas turbine flowmeter: crashes after waking up from sleep or replacing a battery 关闭

    The main reason for this situation is that the power on reset circuit is abnormal or the crystal oscillator circuit is not working.
    The solution is to reinstall the battery or short circuit the large electrolytic capacitor under the discharge battery box after power outage, which can also be solved directly through the reset button.

  • Gas turbine flowmeter: Instantaneous flow rate display is unstable 关闭

    1. When the sensitivity requirement of the amplifier is too high or too low, and there is a phenomenon of over counting or under counting pulses, the preamplifier should be replaced at this time;


    2. The turbine rotation of the flowmeter is unstable, and the impeller must be reinstalled or dirt removed.


  • Gas turbine flowmeter: No output signal after normal power on 关闭

    1. If the fluid flow rate in the pipeline is lower than the starting flow rate of the flowmeter or there is no fluid flow rate, the solution is to increase the fluid flow rate to meet the flow rate requirements of the flowmeter.


    2. There is an error in the connection of power and signal outputs. The solution is to correctly connect the circuit according to the circuit diagram.


    3. The preamplifier of the calculator is damaged (at this time, the calculator does not count and the instantaneous value is 0) or the driver amplifier circuit is not working (the calculator is working normally). At this point, replacing damaged electrical components can solve this problem.
  • Gas turbine flowmeter: There is no medium flow in the pipeline, and the flowmeter shows flow rate 关闭

    1. If the power system is unstable or other electrical control interference occurs, a power regulator should be added to eliminate strong current and magnetic field interference.


    2. When the grounding system of the flowmeter is poor or is affected by other strong currents and grounding interference, grounding should be used correctly and some other factors should be eliminated.


    3. If the sensitivity requirement of the amplifier is too high or self excitation occurs, the amplifier should be replaced.
  • The data measured by ultrasonic open channel flowmeters fluctuates greatly 关闭

    It is possible that the water surface is not calm and fluctuates greatly. Electromagnetic noise interference, inverter noise, and ultrasound can encounter false water surface reflection targets. Ultrasound enters a dead corner, and the detector and main body wiring are incorrect.


    Solution: Try to install it in a stable place on the water surface, replace the power supply or use an isolated power supply. The main body should be reliably grounded separately, and be far away from the inverter. Replace the installation device to avoid the ultrasonic waves emitted by the probe hitting both sides of the water path and other obstacles. According to the instructions, rewire the wiring. If there is an extension cable midway, please pay attention to the wiring sequence and connect the shielding layer of the wire.

  • The ultrasonic open channel flow meter system enters a falling wave state and enters the liquid level display screen. The small horn symbol on the screen remains unchanged, displaying a triangle. 关闭

    This state indicates that the system is in a loss of wave state. The possible reason is that the measured distance exceeds the range of the flowmeter. The measured medium has strong disturbances, waves, agitation, etc. There are strong interference sources such as frequency converters and motors around. The probe is not aligned with the measured plane. There are obstacles such as support rods and material openings in the measured space. The liquid level has entered a dead corner.


    Solution:
    1. When the measured distance exceeds the range, it is necessary to replace the flowmeter with a larger range. If there is noise, the machine will automatically resume normal measurement after the measured medium stabilizes, or use a waveguide tube with a diameter of 150mm to install the flowmeter;
    2. Open channel flowmeter grounding, power isolation, output signal line isolation;
    3. Recalibrate the probe, the probe must be perpendicular to the measured page. Choose a suitable installation location again and try not to cause interference. The installation height of the probe should not be too high, and the installation height of the probe's radial surface should be greater than the distance between the upper limit of the liquid level and the dead angle.

  • The ultrasonic open channel flowmeter does not display 关闭

    The ultrasonic open channel flowmeter did not display, possibly due to a lack of power connection, poor contact of the LCD panel, and damage to the LCD panel.


    Solution: Check the power cord and measure the voltage; Reseat the LCD screen and its wiring; Replace the LCD screen.